Human NTF3 (Neurotrophin-3) CLIA Kit for Quantitative Detection

Katalog-Nummer NB-22-41028-96

Size : 96T

Marke : Neo Biotech


✓ 1-Year Performance Guarantee | SDS & Datasheet Included | Expert Tech Support | Covered by

General Information

Short DescriptionThis human NTF3 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes in serum, plasma and other biological fluids.
ApplicationsCLIA
ReactivityHuman
Sensitivity9.38pg/mL
Detection Limit15.63~1000pg/mL
NoteFOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.

Product Properties

Storage InstructionIf unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time3.5h
DetectionChemiluminescence

Target Information

Gene Symbol
Gene ID
Uniprot ID
SpecificityThis kit recognizes Human NT-3 in samples. No significant cross-reactivity or interference between Human NT-3 and analogues was observed.
Sample TypeSerum, plasma and other biological fluids

Additional Info

Tissue Specificity Brain and peripheral tissues.
Function Seems to promote the survival of visceral and proprioceptive sensory neurons.
Protein Name Neurotrophin-3
Nt-3
Hdnf
Nerve Growth Factor 2
Ngf-2
Neurotrophic Factor
Database Links







Cellular Localisation Secreted
Alternative CLIA Names Neurotrophin-3 CLIA kit
Nt-3 CLIA kit
Hdnf CLIA kit
Nerve Growth Factor 2 CLIA kit
Ngf-2 CLIA kit
Neurotrophic Factor CLIA kit
NTF3 CLIA kit
Specificity This kit recognizes Human NT-3 in samples. No significant cross-reactivity or interference between Human NT-3 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 96-112 103
EDTA plasma(n=8) 98-116 106
Cell culture media(n=8) 102-118 108

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 53.73 84.81 399.67 51.47 80.06 421.55
Standard deviation 4.53 9.77 37.37 5.41 9.54 36.84
CV (%) 8.43 11.52 9.35 10.51 11.92 8.74

Citations

Product Review

Well-cited Academic Publications
KO-Validated 700+ Lines
Technical Support Expert Scientific Team
1-Year Guarantee Antibodies & Proteins