Mouse Estradiol,E2 ELISA Kit

Cat# CSB-E05109m-96T

Size : 96T

Brand : Cusabio


CSB-E05109m
Size 96T,5×96T,10×96T

Product Details

Associated names
N/A
Abbreviation
E2
Species
Mus musculus (Mouse)
Sample Types
serum, plasma
Detection Range
50 pg/ml-1200 pg/ml.
Sensitivity
40 pg/ml.
Assay Time
1-5h
Sample Loading Volume
50-100ul
Detection Wavelength
450 nm
Research Area
Signal Transduction
Assay Principle
quantitative
Measurement
Competitive
Precision

Intra-assay Precision (Precision within an assay): CV%<15%

Three samples of known concentration were tested twenty times on one plate to assess.

Inter-assay Precision (Precision between assays): CV%<15%

Three samples of known concentration were tested in twenty assays to assess.

Typical Data

These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.

pg/ml

OD1

OD2

Average

0

2.185

2.254

2.220

50

1.176

1.167

1.172

120

0.743

0.718

0.730

250

0.518

0.529

0.524

500

0.340

0.321

0.331

1200

0.177

0.168

0.172

ELISA Data Analysis
Troubleshooting
and FAQs
Storage
Store at 2-8°C. Please refer to protocol.
Shelf Life
6 months
Description

This Mouse Estradiol (E2) ELISA Kit was designed for the quantitative measurement of Mouse Estradiol (E2) protein in serum, plasma. It is a Competitive ELISA kit, its detection range is 40 pg/ml-1000 pg/ml and the sensitivity is 40 pg/ml.

Citations

  • BR Borah, JC Kalita, M Das,Comparative Clinical Pathology,2026
  • Y Dai, Y Guo, D Chen, P Li, L Xue, Y Feng,Journal of Translational Medicine,2026
  • C Salaün, M Huré, C Guérin, C Bôle-Feysot,Gut Microbes,2026
  • Polystyrene Nanoplastics induced placental toxicology by activating Keap1-mediated ferroptosis via METTL3-dependent m6A methylation C Yujiao, L Yifan, Z Meng, L Shanshan, Y Yousheng,Cell biology and toxicology,2026
  • J Zhu, P Wu, Y Ma, Z Peng, H Fa, L Qin, M Geng,Nature Communications,2026
  • T Wu, Y Feng, Q Zhu, T Jiang, Y Gao, K Nie,Advanced Science,2026
  • S Wei, D Chen, J Wang, C Wu, W Tang, L Xue,Journal of Advanced Research,2026
  • Y Wu, Y Chen, S Wang, T Wu, J Zhang,Reproductive Toxicology,2026
  • X Zeng, H Xie, W Zhang, Y Yu, M Wang, Y Jiang,SSRN,/
  • Y Ma, Z Jin, A Yang,Journal of Ovarian Research,2025

Customer Reviews and Q&A

Average Rating:
5.0 - 4 reviews

Sample type: Serum

Sample species: Mouse

Sample dilution: 1:5

Review: It is very convenient that the standard song does not have to match itself, and the basic trend of the experimental results is the same, and the standard song is better

By Anonymous

Sample type: Serum

Sample species: Mouse

Sample dilution: No dilution

Review: I used CSB-L05109m to detect the normal serum level of sex hormone E2. The OD value of the standard curve was 1.7585-0.2015, the OD value of the sample was 0.804-1.423, and the R value of the standard curve was 0.99837.

By Anonymous

Sample type: Serum

Sample species: Mouse

Sample dilution: No dilution

Review: The results of CSB-E05109m detection of E2 without configuring the standard curve themselves are that the gradient is obvious and the repeatability of the double standard curve is better. We used mice