NeoSpin
Description
|
|
Applications
- Protein Concentration, Nucleic Acid Concentration, Buffer Exchange, Dialysis, Desalting
Dead stop
- Avoid spinning to dryness: The process does not require complete drying through spinning.
- Predictable concentration factor: Provides a reliable and predictable concentration factor.
- No need for calibration: No calibration is necessary when running multiple samples in parallel.
- Vertical membranes: The membranes are aligned with the filtrate instead of being perpendicular, leading to fewer clogs, reduced waste, and faster filtration.
- Single-step concentration: Capable of achieving 25- to 80-fold concentration in a single step.
Reliable
- Spin precious samples confidently: The unit allows for spinning precious samples with confidence.
- Robust and sleek design: The unit is designed to be sturdy and aesthetically pleasing.
- Leakage prevention: The unit is designed to prevent leakage, ensuring the integrity of the samples.
- Neutrally charged ultrafiltration membrane: The membrane has a neutral charge, resulting in low binding properties that enhance flux (filtration rate) and sample recovery.
- Excellent chemical resistance: The membrane exhibits high resistance to chemical substances, ensuring compatibility with a wide range of samples and solvents.
- Very low extractable: The membrane has minimal leaching of substances, ensuring that the filtered samples are not contaminated with unwanted compounds.
Temperature range: -20°C to +50°C
Autoclavability:
- No
Processing of protein solutions containing biomolecules (albumin, mAbs, lgG, lgM, hormones, growth factors, etc.)
• Acetic Acid (>25%)
• Acetonitrile (>30%)
• Aliphatic & aromatic esters
• Amines
• Ammonium hydroxide (>5%)
• Aromatic & chlorinated hydrocarbons
• Butyl acetate (>40%)
• Dimethyl acetamide (DMAC) (>30%)
• Ethers • Hydrochloric acid (>0.5 Nat 50°C)
• Isopropyl Alcohol (> 25%)
• Ketone • Methylene chloride (>1%)
• Methyl ethyl ketone (>1%)
• Phosphoric acid (>1 N)
• Sodium deoxycholate (>5%)
• Sodium hydroxide (>0.5N at 50°C)
• Sodium hypochlorite (>0.04%)
• Tetrahydrofuran (>5%)
• Toluene (>1%)
List of Products
Cat# | Description | Cond. |
NB-57-0006 | NeoSpin 5KD - Centrifugal Filters (Max sample volume 5 ml) | 24 pcs |
NB-57-0007 | NeoSpin 10KD - Centrifugal Filters (Max sample volume 5 ml) | |
NB-57-0008 | NeoSpin 30KD - Centrifugal Filters (Max sample volume 5 ml) | |
NB-57-0009 | NeoSpin 50KD - Centrifugal Filters (Max sample volume 5 ml) | |
NB-57-0010 | NeoSpin 100KD - Centrifugal Filters (Max sample volume 5 ml) | |
NB-57-0001-1 | NeoSpin 5KD - Centrifugal Filters (Max sample volume 15 ml) | 8 pcs |
NB-57-0001-2 | 24 pcs | |
NB-57-0002-1 | NeoSpin 10KD - Centrifugal Filters (Max sample volume 15 ml) | 8 pcs |
NB-57-0002-2 | 24 pcs | |
NB-57-0003-1 | NeoSpin 30KD - Centrifugal Filters (Max sample volume 15 ml) | 8 pcs |
NB-57-0003-2 | 24 pcs | |
NB-57-0004-1 | NeoSpin 50KD - Centrifugal Filters (Max sample volume 15 ml) | 8 pcs |
NB-57-0004-2 | 24 pcs | |
NB-57-0005-1 | NeoSpin 100KD - Centrifugal Filters (Max sample volume 15 ml) | 8 pcs |
NB-57-0005-2 | 24pcs |