Nipah Virus Glycoprotein (G) Human IgM ELISA Kit

Cat# IEQ-NiVG-IgM-5

Size : 5PlateKit

Marca : RayBiotech


Nipah Virus Glycoprotein (G) Human IgM ELISA Kit

The RayBiotech Nipah Virus Glycoprotein (G) Human IgM ELISA Kit is an in-vitro indirect ELISA for the quantitative measurement of Human IgM antibody against Nipah Virus Glycoprotein (G) in serum or plasma samples. This product is for research use only. Not for therapeutic or diagnostic applications.
Contact Us for Bulk Request

Product Description

Specifications

Size1 Plate Kit, 2 Plate Kit, 5 Plate Kit
SpeciesHuman, Nipah Virus
Compatible Sample TypesPlasma, Serum
Gene Symbols
IgM
Protein Name / Synonyms
IgM; Nipah Virus Glycoprotein (G)
Quantitative/Semi-QuantitativeSemi-Quantitative
Solid Support
96-well Microplate
Design PrincipleIndirect
Method Of DetectionColorimetric
Research AreaInfectious Disease, Hemorrhagic Fever
Shipping TypeDry ice (additional shipping fee)
Storage-20°C

Introduction

This in-vitro ELISA kit employs an indirect ELISA method. Standard 96-well plates are coated with the pathogen antigen, which combines with the corresponding antibody present in a sample and positive control, which is used as a calibration curve for interpretation purposes. When a biotinylated secondary anti-human IgA/G/M antibody is added, a complex forms between the biotinylated secondary antibody and human antibody bound to the protein-coated plate. A TMB substrate is added, and a blue color is generated. The depth of color is relative to the amount of the human anti-pathogen antigen antibody present. The stop solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm.

The Positive Control consists of an anti-pathogen antigen antibody. A biotinylated anti-positive control antibody is added to the positive control wells and treated identically to the samples. The intensity of the resulting color (measured at 450 nm) is used as a calibration curve for interpretation purposes in the different assays.

Kit Components

Component Size / Description
Pathogen antigen coated 96-well Microplate 96 wells (12 strips x 8 wells) coated with pathogen antigen
Wash Buffer Concentrate (20X) 25 ml of 20X concentrated solution
Positive Control 1 vial of Positive Control sample containing anti-pathogen antigen antibody
Biotinylated Anti-Human Ig(A/G/M) 1 vial of solution
Biotinylated Anti-Positive Control 1 vial of solution
HRP-Streptavidin concentrate 1 vial of solution
TMB One-Step Substrate Reagent 12 ml of 3,3,5,5'-tetramethylbenzidine (TMB buffer solution)
Stop Solution 8 ml of 0.2 M sulfuric acid
Assay Diluent B 15 ml of 5X concentrated buffer
5X Sample Diluent 25 ml of 5X diluent buffer, 0.5% proclin 300 as preservative

Additional Materials Required

  • Microplate reader capable of measuring absorbance at 450 nm
  • Shaker
  • Pipettes capable of accurately delivering 2 ul to 1 ml volumes
  • Adjustable 1-25 ml pipettes for reagent preparation
  • Graduated cylinders: 100 ml and 1 liter
  • Distilled or deionized water
  • Absorbent paper

Assay Procedure Summary

  1. Prepare all reagents, samples and standards as instructed.
  2. Add 100 µl positive control, or sample to each well. Incubate 1 hour at room temperature.
  3. Add 100 µl prepared Biotinylated Anti-Positive Control and Biotinylated Anti-Human Ig(A/G/M) Antibody into respective wells. Incubate 1 hour at room temperature.
  4. Add 100 µl prepared HRP-Streptavidin solution to each well. Incubate 30 minutes at room temperature.
  5. Add 100 µl TMB One-Step Substrate Reagent to each well. Incubate 30 minutes at room temperature.
  6. Add 50 µl Stop Solution to each well. Read at 450 nm immediately.

Storage / Stability

The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C. For prepared reagent storage, see table below.