- An assay plate --- The 96-well plate is composed of 12 x 8 strip plates and can be taken apart.
- Two bottles of lyophilized standard --- Reconstitute one bottle of the standard with sample diluent at dilution series and draw the standard curve.
- Biotin-labeled LPS antibody (100 x concentrate) 1 x 120 μl --- Act as the detection antibody and need to be diluted before use.
- HRP-avidin (100 x concentrate) 1 x 120 μl --- Catalyze the TMB substrate for color development and need to be diluted before use.
- Biotin-antibody Diluent 1 x 15 ml --- Dilute the Biotin-antibody.
- HRP-avidin Diluent 1 x 15 ml --- Dilute the HRP-avidin.
Human Lipopolysaccharides,LPS ELISA Kit
Cat# CSB-E09945h-96T
Size : 96T
Marca : Cusabio
| Size | 96T,5×96T,10×96T |
Product Details
| Intra-assay Precision (Precision within an assay): CV%<8% | ||||||
| Three samples of known concentration were tested twenty times on one plate to assess. | ||||||
| Inter-assay Precision (Precision between assays): CV%<10% | ||||||
| Three samples of known concentration were tested in twenty assays to assess. | ||||||
| To assess the linearity of the assay, samples were spiked with high concentrations of human LPS in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | ||||||
| Sample | Serum(n=4) | |||||
| 1:1 | Average % | 88 | ||||
| Range % | 82-94 | |||||
| 1:2 | Average % | 95 | ||||
| Range % | 91-99 | |||||
| 1:4 | Average % | 92 | ||||
| Range % | 87-96 | |||||
| 1:8 | Average % | 94 | ||||
| Range % | 89-99 | |||||
| The recovery of human LPS spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | ||||||
| Sample Type | Average % Recovery | Range | ||||
| Serum (n=5) | 93 | 90-97 | ||||
| EDTA plasma (n=4) | 88 | 82-96 | ||||
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
- A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
- An incubator can provide stable incubation conditions up to 37°C±5°C.
- Centrifuge
- Vortex
- Squirt bottle, manifold dispenser, or automated microplate washer
- Absorbent paper for blotting the microtiter plate
and FAQs
This Human LPS ELISA Kit was designed for the quantitative measurement of Human LPS protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 6.25 pg/mL-400 pg/mL and the sensitivity is 1.56 pg/mL .
Citations
- Y Wang, G Zhang, S Lin, X Zhuang,Scientific Reports,2026
- L Guan, X Li, C He, P Zheng, Y Zou, Q Zhu,Advanced Science,2026
- L Klümpen, A Mantri, A Donkers, W Seel,Gut Microbes,2026
- X Yan, X Zhang, L Wang, W Song, T Qi,Frontiers in Cellular and Infection Microbiology,2026
- H Liang, X Ding, S Liu, S Tong, X Wang, Z Zhang,Gut Microbes,2026
- L Xie, R Zhang, H Zou, J Hu, J Deng, J Ding, L Liu,Science Advances,2026
- A Simón Rueda, C Sánchez-Menéndez,Frontiers in Immunology,2025
- S Yang, S Feng, H Wu, C Zhong, S Zhan,Clinical Interventions in Aging,2025
- L Loffredo, E Maggio, S Bartimoccia, A Magna,Antioxidants,2025
- A Schieren, H Huber, C Alvarez-Garavito, A Mantri,medRxiv,2025
Customer Reviews and Q&A
There are currently no reviews for this product.
I would like to know if this ELISA kit is SPECIFIC for LPS of Escherichia Coli
I mean CSB-E09945h ELISA kit
CSB-E09945h detects the residual LPs in the human body due to infection.Pls let me know if you have any further questions. Thank you.
Could you share with me what the antibodies in this kit bind to CSB-E09945h?
CSB-E09945h
Capture antibody is mouse monoclonal antibody and detection antibody is goat polyclonal antibody.Pls let me know if you have any further questions. Thank you.
I have an interest in knowing product information "Human Lipopolysaccharides, LPS ELISA Kit" CSB-E09945h.
It is used to measure circulating levels of Gut-Derived Serum Lipopolysaccharide?
How many blood samples or individuals can be analyzed with the kit?
CSB-E09945h
For a 96T kit, it can test 88 samples. If you run dupliacated wells, it can test 44 samples.
Pls follow actual test result if you want to test Gut-Derived Serum Lipopolysaccharide.Pls let me know if you have any further questions. Thank you.
I'm wondering why there are different ELISA kits against different species. Is it because of the variation of LPS? Can I use the human LPS ELISA to measure the LPS in mouse plasma?
Human LPS ELISA kit is used to test human samples, while mouse LPS ELISA kit is used to test mouse samples. Detection of cross-species is not advised. Because different species are different in the matrix.