Alpha‑Galactosidase Activity Assay Kit (Fluorometric)
Product Description
Specifications
| Size | 1 Plate Kit, 2 Plate Kit, 5 Plate Kit |
| Sensitivity | 0.03 µU |
| Compatible Sample Types | Plasma, Serum, Cell Lysates, Saliva, Urine |
| Quantitative/Semi-Quantitative | Quantitative |
| Solid Support | 96-well Microplate |
| Method Of Detection | Colorimetric, Fluorometer |
| Research Area | Glycolysis & Lipid Metabolism |
| Shipping Type | Blue ice |
| Storage | -20°C |
Introduction
Alpha-Galactosidase (α-Gal) hydrolyzes alpha-galactosyl moieties found in glycolipids and glycoproteins. In mammals, α-Gal hydrolyzes poly- and oligosaccharides commonly found in dietary sources that are difficult to digest. Therefore, α-Gal is used in dietary supplements that help to reduce the production of intestinal gases due to consumption of certain foods. It is known total α-Gal activity is due to two major isozymes with unique, yet different thermostability profiles. Alpha-Galactosidase A, is thermolabile and represents approximately 90% of total α-Gal activity. Fabry Disease, a lysosomal disease disorder, is characterized by mutations in alpha-Galactosidase A. These mutations cause abnormal accumulation of glycosphingolipids in lysosomes.
Alpha‑Galactosidase Activity Assay Kit provides a simple, reproducible, and sensitive tool of measuring the activity of alpha‑Galactosidase in cell lysates, plasma, serum, urine, saliva and other biological liquid samples. In this assay, alpha‑Galactosidase cleaves a synthetic specific substrate releasing a fluorophore. The fluorescence signal is measured at Ex/Em = 360/445 nm. The increase in fluorescence intensity is directly proportional to alpha‑Galactosidase activity in the sample.
Kit Components
| Component | Size / Description |
|---|---|
| Microplate | A 96-well plate |
| Assay Buffer | 15 mL |
| Stop Solution | 25 mL |
| Fluorescence Standard | 1 vial |
| α-Gal Substrate | 1 vial |
| α-Gal Positive Control | 1 vial |
Additional Materials Required
- Microplate reader capable of measuring fluorescence intensity at Ex/Em = 360/445 nm
- Precision pipettes to deliver 2 μL to 1 mL volumes
- Incubator at 37°C
- Tubes to prepare sample dilutions
- 15 mL and 50 mL conical tubes
- MilliQ water or another type of double distilled water (ddH2O)
Assay Procedure Summary
- Add 40 µL of samples, positive control, substrate background to the 96-well microtiter plate (black bottom).
- Add 60 µL of standard to the 96-well microtiter plate.
- Add 20 µL diluted α-Gal substrate solution to each well, but not the standard wells. Carefully shake the plate for a few seconds to mix.
- Incubate at 37°C for 30 minutes with mixing, protect from light.
- Add 200 µL Stop Solution. Put the plate on a shaker for 2 minutes to mix well (protect from light).
- Read the fluorescence signal with a fluorescence plate reader at Ex/Em = 360/445 nm.